← Journal
Project & Design Process · 23 November 2026

Which Button Is the Kitchen? Labelling KNX Push Buttons So the Whole House Can Use Them

A blank six-button KNX keypad makes sense to the owner and nobody else. How to choose engraved symbols or text, keep button layouts consistent, use status LEDs properly and sign off the button map before anything is ordered.

Which Button Is the Kitchen? Labelling KNX Push Buttons So the Whole House Can Use Them

December is coming. In a lot of Joburg homes that means the house-sitter moves in, the in-laws arrive from the coast, or the family goes away and a neighbour pops in to feed the cats.

And every one of those people will stand at the front door at night, looking at a six-button keypad with nothing on it, and press buttons until something happens.

The owner knows the top left is the entrance lights and the bottom right is “everything off”. The owner has lived with it for two years. Nobody else has a clue.

That isn’t a KNX problem. It’s a labelling problem, and it gets decided far too late.

A keypad with no labels is a manager who never wrote anything down

Picture a manager who runs the office brilliantly. Every process lives in his head. Then he goes on leave and the intern has to run things for two weeks.

The intern isn’t stupid. He just has no notes. So he guesses, and some of his guesses switch off the server.

A blank keypad is that manager. It works perfectly for the one person who set it up, and only for them. A good button layout is the handover note, printed on the wall where the guest is already looking.

Why it keeps getting left to the end

On most projects the button map is the last thing anyone thinks about. The architect has drawn the switch positions. The electrician has put in the back boxes. The integrator knows roughly what each keypad should do. Then the order goes in with plain rockers, because “we’ll sort out the labels later”.

Later is the problem. Engraved and printed rockers are made for your project. Ekinex, for example, prints or engraves from its own symbol library, and will do custom symbols or text “on request, but only in vector format (ai, eps, pdf, dxf)”. That means somebody has to decide exactly what goes on every button before the order is placed, not after the house is occupied.

What your options actually are

With the two ranges I use most, there are real choices here.

Ekinex marks its rockers in two ways depending on the material. On the FF/71 series, plastic and Fenix NTM rockers are UV printed, and metal rockers are laser marked. On the 20venti series, the plastic rockers are laser marked. The symbol library is large. It covers lighting, blinds and curtains, doors and garage, climate, energy, security, multimedia and a long list of scene icons, plus simple markers like arrows, plus and minus, and on/off.

Hager takes a different route on some of its ranges. The B.IQ push buttons use a clear labelling field that is laser printed and can be lit from behind by the status LED. Hager also has an online labelling tool for its Berker KNX ranges, where you pick the series, the number of buttons, then the icons and text for each one.

So the hardware is not the limit. The limit is whether anyone sat down and decided what each button says.

Symbols or words?

My rule is simple. Use symbols for things everyone already understands, and words for things that are specific to this house.

A light bulb, a blind with an up arrow, a thermostat: nobody needs those explained. Anywhere in the world, people get them.

Scenes are different. “Dinner”, “Movie”, “Pool”, “Goodnight”. A candle icon could mean dinner, or it could mean “romantic”, or nothing at all. If a button runs a scene, write the name of the scene on it. Short words. One word where you can.

And never label a button with something only the integrator understands. “Zone 3” means nothing to a house-sitter. “Patio” does.

The same button in the same place, in every room

This matters more than the engraving.

If the main light is the top-left button in the lounge, make it the top-left button in every room. If blinds sit on the right with up on top, keep them there everywhere. If there’s an “All off” button by the front door, put it in the same position by the back door and the garage door too. (I wrote about central off buttons a week ago, and this is where they pay off.)

Once someone has used two rooms, they can guess the third. That’s what you are designing for. A guest won’t read your labels carefully. They’ll reach for where the light was in the last room.

Use the LEDs for something useful

Most KNX push buttons have status LEDs, and they’re often left on whatever the default was.

The Hager push button application, for example, lets you set each LED to always off, always on, or acknowledgement, and to show the actual status of what the button controls. It also has separate day and night brightness, with night brightness defaulting to 20%.

Use that. At night, a keypad that glows softly is easy to find in a dark passage without lighting up the bedroom. A status LED that follows the real state of the light tells you whether the patio lights are still on without walking outside. That only works if the LED is linked to the actuator’s status feedback, not just to the last button press. (Same lesson as the wall switch LED that goes out of sync.)

Hidden functions don’t count as functions

KNX buttons can do different things on a short press and a long press. The Hager application lets you set the long-press threshold anywhere from 400 ms to 1 s, with 500 ms as the default. Integrators love this. You can put a scene on a short press and save the scene on a long press, or dim on a hold.

Here’s the catch. Nobody will ever find a function they can’t see. If a button does something on a long press, either the label says so, or the function lives somewhere the owner knows about. For guests, assume each button does exactly one thing, and that thing is printed on it.

How I’d run it on a project

  1. Write the button map at design stage. Every keypad, every button, what it does, what it says. One page per room.
  2. Print it at full size. Stick the paper version on the wall where the keypad will go, at the right height, before first fix is closed up. Walk the house with the client.
  3. Ask the “visitor” question. Would the person who looks after the house in December understand this keypad with no help? If not, change the label, not the visitor.
  4. Lock it in before ordering. Engraved rockers get ordered from the signed-off map. Changing your mind afterwards means new rockers.
  5. Put the map in the handover pack. Next to the ETS file, so the next integrator knows what the owner expects each button to do.

The test

When the house is finished, hand the keys to someone who has never been inside. A friend, a neighbour, the person who’ll house-sit in December. Ask them to put the lights on in the kitchen, close the blinds in the main bedroom and switch everything off on the way out.

If they can do that without phoning you, the buttons are labelled properly. If they can’t, you’ll know exactly which ones to fix.

If you’re planning a new build or a renovation and want the switches to make sense to everyone who walks in, I’m happy to talk it through. Just a conversation about what the project needs.

wayne@knxlogic.co.za | 082 564 3982 | www.knxlogic.co.za


Sources

Planning a build or renovation? See what we automate, the hardware we specify, or common KNX questions.

Start with a conversation
about what the project needs.

Phone
+27 82 564 3982
Email
wayne@knxlogic.co.za
Based in
Johannesburg · working nationwide